ALKEN® PDE 901
Effective Date: 02/28/2007
Manufacturer's Name: Alken-Murray Corporation | |
Manufacturer's Address: P.O. Box 400, New Hyde Park, New York 11040 | |
T: 540-636-1236 Fax: 540-636-1770 | |
E-mail: msds@alken-murray.com | |
Manufacturer's Cage Code: 2A384 | |
For chemical emergency - spill, leak, fire or accident - call CHEMTREC - day or night - (800) 424-9300 or outside the USA (703) 527-3887 |
NFPA Hazard Ratings: |
Synonyms: | None |
Product type: | Cold flow additive for distillate fuel/crude oil |
CAS Number: | Not applicable to mixtures |
Chemical Formula: | Proprietary Mixture |
Formula ID Codes: | 901 |
Chemical Name | CAS Number | OSHA PEL | ACGIH TLV | % Weight |
Petroleum Naptha | ||||
Xylene | ||||
Trimethylbenzene | ||||
1,2,4-Trimethylbenzene | ||||
Ethylbenzene | ||||
1,3,5-Trimethylbenzene | ||||
Cumene |
Emergency Overview: WARNING: Harmful if Inhaled; Causes Respiratory tract irritation; harmful if absorbed through skin; may cause chronic health effects based on data with laboratory animals. |
Ingestion: Based on data from components
or similar materials. Swallowing material may cause irritation of the gastrointestinal
lining, nausea, vomiting, diarrhea and abdominal pain. Ingestion of this
material may cause headache, dizziness, incoordination and general weakness.
|
|
Flash Point: 38 degrees C (100.4 degrees F) tested by Pensky-Martens Closed Cup Method (Precision Scientific brand electric flashpoint tester) Flammability Limits: NA Autoignition temp: NA Fire Extinguishing Media: Carbon dioxide, dry chemical, foam Special Fire-Fighting Information: Wear Wear NIOSH-approved SCBA. Water may cause splattering. Material will float on water. Use water spray to cool containers. Isolate product from fire. Unusual Fire and Explosion Hazards: Toxic fumes, gases and vapors may evolve on burning. Vapors are heavier than air and may travel along the ground to a distant ignition source and flash back. Container may rupture on heating. . |
Land Spill: Evacuate all non-essential personnel.
Personal Protective Equipment must be worn, see Personal Protection Section
for PPE recommendations. Eliminate sources of ignition. Prevent additional
discharge of material, if possible to do so without hazard. Recover for
use if possible, or transfer to suitable container for disposal. Use absorbent
to clean up. Prevent liquid from entering sewers, water sources, or low
areas. Contain spilled liquid with sand or earth. Do not use combustible
materials, such as sawdust, to absorb spill. Wash down spill area with soap
and water. Consult an expert on disposal of recovered material and ensure
conformity to local disposal regulations.
|
Loading temperature: 60 deg. C, 140 deg. F Store in cool dry place away from heat, sparks, open flame, oxidizing agents. Keep container closed when not in use. Open container in a well-ventilated area. Do not pressurize, cut, heat, weld or expose containers to flame or other sources of ignition. Do not discharge to drains or the environment, dispose to an authorized waste collection point. Wash thoroughly after handling. Empty containers retain material residue For rapid bioremediation of hard surface spills, use Alken Clear-Flo 5100 |
|
|
|
|
|
RCRA Hazard Class (if discarded): Combustible D001. This material, if discarded, is a hazardous waste under RCRA Regulation 40 CFR 261. Waste management should be in compliance with federal, state and local laws. Material, if discarded, is expected to be hazardous under RCRA due to ignitability 20 - 30% Ethylbenzene CAS #25551-13-7. |
|
|
16. Other Information Reason for Revision: Routine Review & Revision Alken-Murray Corporation provides the information contained herein in good faith, in compliance with the Occupational Safety and Health Act of 1970, but makes no representation as to its comprehensiveness or accuracy. This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Alken-Murray warrants that this product is of merchantable quality. The implied warranty of fitness for a particular purpose is limited to the extent the products are used for the purpose or uses described on the product's label or in any written instructions or materials distributed to the buyer by Alken-Murray and is hereby disclaimed should buyer use the products in a manner inconsistent with this uses or purposes described therein. In no event shall Alken-Murray be liable for any consequential, exemplary, or incidental damages incurred by buyer even if it has been advised of the possibility of such damages. |